The protocols at a glance
| Protocol | Link | Typical equipment | Read by Solar Outlook |
|---|---|---|---|
| Bluetooth Low Energy broadcasts | Wireless | Victron Instant Readout, BTHome, Ruuvi, Mopeka and Govee sensors | Yes |
| Bluetooth Low Energy connections | Wireless | Battery BMS apps, VictronConnect, BT-1 and BT-2 modules | Yes |
| VE.Direct | Serial cable | Victron MPPT chargers, BMV and SmartShunt monitors, Phoenix inverters | Through a Bluetooth dongle |
| VE.Bus | Wired network | MultiPlus and Quattro inverter/chargers | Through the VE.Bus Smart dongle broadcast |
| VE.Can and battery CAN bus | Wired network | Larger Victron chargers, Lynx, GX devices, CAN-enabled lithium batteries | No |
| Modbus RTU (RS485 or RS232) | Serial cable | Renogy and EPEver controllers, many inverters and batteries | Through Renogy and EPEver Bluetooth adapters |
| Modbus TCP and MQTT | Network | Victron GX devices running Venus OS | No |
Bluetooth Low Energy
Bluetooth Low Energy works in two ways. Broadcasts (advertisements) send readings to anything listening, with no connection: Victron Instant Readout, BTHome sensors such as Shelly BLU, RuuviTags and Mopeka tank sensors all work like this.[1] A connection links one reader to one device, which can then ask for values or change settings. Most battery BMS boards and the Renogy BT-1 and BT-2 modules use connections, and usually accept only one at a time.
Victron’s broadcasts are encrypted with a key per device. See Victron Instant Readout explained and which Bluetooth BMS your battery uses for the details.
VE.Direct
VE.Direct is the serial port on Victron MPPT chargers, BMV and SmartShunt battery monitors and Phoenix inverters. In text mode it sends a block of labelled values about once a second. In HEX mode a reader can ask for individual registers and change settings.[2]
Victron sells a VE.Direct to USB cable and a VE.Direct Bluetooth Smart dongle. If you build your own connection, Victron recommends galvanic isolation, and signal levels differ: Phoenix inverters use 3.3 V and MPPT chargers 5 V. The port’s power pin supplies only a small current, so power an ESP32 separately.[3]
VE.Bus
VE.Bus links Victron’s MultiPlus and Quattro inverter/chargers, including parallel and three-phase systems. Reading it needs an MK3-USB interface or a GX device. A VE.Bus Smart dongle adds Bluetooth, including an Instant Readout broadcast with the main values.[4]
VE.Can and CAN bus
CAN bus is a wired network designed for vehicles and industrial equipment. Victron’s version, VE.Can, connects larger solar chargers, Lynx distribution and GX devices. Many lithium batteries for home and larger off-grid systems use a separate BMS-CAN link to tell an inverter or GX device how to charge them.[4]
An ESP32 has a built-in CAN controller (called TWAI) but needs an external transceiver chip to connect to the bus. Solar Outlook doesn’t read CAN at present. In most van systems, a GX device is the usual way to bring CAN data together.
Modbus RTU over RS485 or RS232
Modbus is a simple register-based protocol used by many controllers, inverters and batteries. Renogy controllers expose it on an RS232 or RS485 port, and the BT-1 and BT-2 modules carry it over Bluetooth.[5] EPEver Tracer controllers use RS485 on an RJ45 socket, with the eBox-BLE-01 adapter for Bluetooth.[6]
Each manufacturer publishes or documents its own register map, so check the exact model before relying on a project written for another.
GX devices, Modbus TCP and MQTT
Victron’s GX devices, such as the Cerbo GX, run the open-source Venus OS and gather data from VE.Direct, VE.Bus and VE.Can equipment. They share it on the local network over Modbus TCP and MQTT, and online through VRM. If your system already has a GX device, it’s the most complete source of data.[4]
Sources
Protocol details come from manufacturer documents and open-source projects that publish captures from real equipment. How the guides are researched and corrected.
- BTHome formatOpen broadcast format used by Shelly BLU and other sensors.
- VE.Direct Protocol 3.32 (Victron)Text and HEX framing, product IDs and error codes.
- VE.Direct protocol FAQ (Victron)Isolation, signal levels and power pin limits.
- Data communication with Victron Energy products (whitepaper)Which interface and document applies to each Victron product.
- renogy-btRenogy controllers over BT-1 and BT-2, with Modbus register details.
- EPEver Tracer AN on ESPHome devicesRS485 wiring and Modbus registers for Tracer controllers.