Before you start
You need the ESP32-S3-Touch-LCD-4.3B, with 16 MB flash and 8 MB PSRAM. The 4.3B-BOX is the same board in a case. Other Waveshare 4.3-inch boards need different firmware. Install Solar Outlook from the System Bridge installer, choosing “Waveshare 4.3B touch panel”, then link the panel with the Solar Outlook app (version 1.2.0 or later) on Android or iPhone.
Try the Waveshare 4.3B alpha firmware on a spare panel. The alpha still needs hardware testing, and USB installation erases settings and readings.
Power it from USB-C at 5 V while you set it up. For a permanent installation, use the 7–36 V DC input from your leisure battery, through a fuse.
Work safely
Disconnect the panel’s power before changing any wiring. Everything in this guide is low-voltage DC. If a relay will switch a mains appliance, have that part installed by a qualified electrician.
The terminals
The green terminals on the back are labelled on the case. On the panel, open Settings and tap a terminal’s row (RS485, CAN, I2C, DI0 input, DI1 input, DO0 output or DO1 output) to choose what it’s used for. The panel shows how to wire each one under its choices.
| Terminal | What it does | Status |
|---|---|---|
| SDA, SCL, VOUT, GND | I2C, for wired temperature, humidity and pressure sensors. VOUT supplies 3.3 V or 5 V, set by a resistor on the board. | Working |
| DI0, DI1, DI COM | Two isolated inputs for float switches and door or contact switches, 5–36 V. | Tested with float switches |
| DO0, DO1, GND | Two isolated outputs. Each connects to ground when on, 5–36 V DC, up to 0.45 A. | Tested with a relay |
| A, B | RS485, for some solar chargers, batteries and meters. | Experimental |
| H, L | CAN, for some batteries and Victron VE.Can. Listen only: the panel never sends on CAN. | Experimental |
Bluetooth or wired temperature?
The panel can use a temperature for its readings and for the heating thermostat. Both kinds of sensor work, and they cost about the same, so the choice comes down to where it goes.
Bluetooth sensors
A Bluetooth thermometer needs no wiring and can sit anywhere in Bluetooth range: by the bed, in a locker or outside. It runs on its own battery, usually for months. Solar Outlook reads the Govee H5075 and similar Govee models, the Shelly BLU H&T, RuuviTag and Xiaomi LYWSD03MMC sensors running pvvx or ATC firmware. Xiaomi sensors need that firmware installed first, so the Govee or Shelly is simpler.
Add the sensor in the Solar Outlook app, in the panel’s equipment list. To use it for heating, open Heating on the panel, tap Temperature and choose it. If the chosen sensor stops reporting for five minutes, the heating switches off rather than guessing.
Wired sensors
A wired sensor needs no battery and reads every few seconds, but its cable has to run back to the panel. I2C is meant for short distances, so keep the cable under about a metre. It suits a sensor fixed near the panel, for example in the same cupboard or on the wall beside it.
Wiring an I2C sensor
I2C sensors share two wires, and each chip answers on its own address. The panel’s touchscreen, clock and input/output chip already use several addresses, so a sensor on one of those would clash with them.
| Chip | Reads | Address |
|---|---|---|
| SHT40, SHT41, SHT45 | Temperature, humidity | 0x44 or 0x45 |
| SHT30, SHT31, SHT35 | Temperature, humidity | 0x44 or 0x45 |
| SHT21, HTU21D, Si7021 | Temperature, humidity | 0x40 |
| HDC1080 | Temperature, humidity | 0x40 |
| DHT12 | Temperature, humidity | 0x5C |
| BME680 | Temperature, humidity, pressure | 0x76 or 0x77 |
| BMP280, BME280 | Temperature, pressure (humidity isn’t read from a BME280) | 0x76 or 0x77 |
| QMP6988 (M5Stack ENV III) | Pressure, alongside its SHT30 | 0x70 |
Avoid AHT10 and AHT20 boards. They’re common and cheap, but they use address 0x38, which the panel’s input/output chip already answers on. Also avoid anything set to 0x14, 0x20–0x27, 0x30–0x3F, 0x51 or 0x5D.
Connecting it
- Check which voltage the board’s VOUT supplies (3.3 V or 5 V) and that your sensor board accepts it. The Adafruit SHT40 board accepts either.
- With the panel unpowered, connect SDA to SDA, SCL to SCL, VOUT to the sensor’s power pin (VIN, VCC or V+) and GND to GND.
- On the panel, open Settings, then I2C, and choose Sensors.
- Power the panel. The readings appear once the sensor is found.
On a STEMMA QT or Qwiic cable, red is power, black is ground, blue is SDA and yellow is SCL. On a Grove cable, red is power, black is ground, white is SDA and yellow is SCL. Ferrules or a small terminal block make jumper pins more secure in the screw terminals.
Float switches for tanks
A float switch is a simple two-wire switch that opens or closes as the water level passes it. I’ve tested them on the panel’s inputs and they work well. Each input takes one switch, so two switches give either one tank with low and full levels, or two tanks with one level each.
- With the panel unpowered, connect the float switch’s two wires between DI0 (or DI1) and GND. Leave DI COM unconnected for a plain switch.
- On the panel, open Settings, then DI0 input, and choose what it shows, for example Tank full, closed when normal.
- In Settings, open Tanks, then Add a tank. Give it a name, its type (fresh, waste, toilet or other) and its size, and set where each switch sits.
Choose “closed when normal” where you can, and fit or turn the float so it matches. Then a broken or unplugged wire looks like the level being reached, rather than hiding the fault. Many float switches change between the two by turning the float over on its stem.
The panel waits for a switch to stay put for 10 seconds before believing it, so water sloshing while you drive doesn’t set off alerts. Powered level sensors with an NPN or PNP output also work, using DI COM; follow Waveshare’s wiring for those.
Outputs and relays
Each output (DO0 and DO1) connects to ground when it’s on and is open when it’s off. That’s enough to drive a relay coil or a small load of up to 0.45 A at 5–36 V DC. It can’t switch mains or anything heavier itself, so use it to drive a relay, and let the relay’s contacts switch the load.
Wiring a relay
- Connect one end of the relay coil to your battery positive (through a small fuse).
- Connect the other end of the coil to DO0 (or DO1).
- Connect the panel’s output GND to battery negative.
- Wire the relay’s contacts into the circuit you want to switch, with its own fuse.
Use a relay with a diode across its coil. Many automotive relays and relay modules have one built in. It stops the voltage spike when the coil switches off, which could otherwise damage the output over time. Check the coil current is well under 0.45 A; a typical 12 V automotive relay coil draws around 0.15 A.
A relay module whose input switches on when it’s connected to ground (sometimes called a low-level trigger) can also work, with its input connected to the output. I used a 5 V relay module and it switched reliably. Relay modules differ a lot, though, so there’s no guarantee another will behave the same. A plain 12 V relay wired as above is the safer choice.
Setting it up
On the panel, open Settings, then DO0 output. Choose Heater demand to let the panel’s thermostat run a heater, or Switch with a name such as Lights, Water pump or Fan. Switches can then be turned on and off from the panel, the app and switching rules.
For a heater, the relay should switch the heater’s thermostat demand wire, never its power feed, so the heater still runs its own cool-down. Check your heater’s manual for how its thermostat connects.
The outputs start off whenever the panel starts, and switch off if the panel loses contact with its output chip.
RS485 and CAN equipment
Reading equipment over its wired connections is experimental. It’s still being tested, so don’t rely on it for anything important yet. Bluetooth remains the dependable way to read your equipment.
On RS485, the panel can try EPEver and Renogy solar chargers, Renogy batteries, JBD battery management systems, PZEM-017 DC meters and XY-MD02 sensors, or listen for equipment with Find equipment. Connect A to the equipment’s A (or D+) and B to its B (or D−), using a twisted pair. On CAN, the panel can listen for Pylontech-style batteries and Victron VE.Can, with H to CAN-H and L to CAN-L. It only reads; it never changes settings on wired equipment.
Each bus needs a terminating resistor at both ends; the board has a switch for its own. If you try one of these and it works, or doesn’t, please let me know.
Shopping list
These are examples I’ve checked, not affiliate links. Prices and stock change, so confirm the model before ordering. Prices were checked on 14 November 2026.
| Part | Example | Rough cost |
|---|---|---|
| The panel | Waveshare 4.3B in a case (Amazon UK) or direct from Waveshare | About £50 |
| Bluetooth thermometer | Govee H5075 (Govee UK) | About £10–18 |
| Bluetooth thermometer | Shelly BLU H&T (The Pi Hut) | About £19 |
| Wired sensor | Adafruit SHT40 (The Pi Hut) with a STEMMA QT to jumper cable | About £8 together |
| Wired sensor with pressure | M5Stack ENV III (The Pi Hut) with Grove to jumper cables | About £10 together |
| Float switch | Plastic vertical float switch (ITM Components), or any similar two-wire reed float switch | A few pounds |
| Relay | A 12 V automotive relay with a built-in diode, from a motor factors or electronics supplier | A few pounds |
Choose a float switch rated for drinking water if it goes in your fresh tank.
If something doesn’t work
- A wired sensor isn’t found. Check I2C is set to Sensors, SDA and SCL aren’t swapped, the sensor accepts the VOUT voltage, and its address isn’t one the panel uses.
- A tank shows an alert or the wrong level. Check the input’s choice matches how the switch is fitted: closed when normal or closed when reached.
- An output does nothing. Check its role in Settings, that the relay coil goes to battery positive, and that the output GND goes to battery negative.
- A Bluetooth sensor doesn’t appear. Bring it closer to the panel and check its battery. If it still doesn’t read, please send a report from the app.
Sources
Terminal ratings come from the board’s manufacturer, and sensor addresses from the chip and board makers. How the guides are researched and corrected.
- Adafruit SHT40 guideAddress, supply voltage and STEMMA QT wiring.
- M5Stack ENV III documentationSHT30 and QMP6988 addresses.